Class DescriptorProtos.FieldOptions

java.lang.Object
com.google.protobuf.AbstractMessageLite
com.google.protobuf.AbstractMessage
com.google.protobuf.GeneratedMessageV3
com.google.protobuf.GeneratedMessageV3.ExtendableMessage<DescriptorProtos.FieldOptions>
com.google.protobuf.DescriptorProtos.FieldOptions
All Implemented Interfaces:
DescriptorProtos.FieldOptionsOrBuilder, com.google.protobuf.GeneratedMessageV3.ExtendableMessageOrBuilder<DescriptorProtos.FieldOptions>, com.google.protobuf.Message, com.google.protobuf.MessageLite, com.google.protobuf.MessageLiteOrBuilder, com.google.protobuf.MessageOrBuilder, Serializable
Enclosing class:
DescriptorProtos

public static final class DescriptorProtos.FieldOptions extends com.google.protobuf.GeneratedMessageV3.ExtendableMessage<DescriptorProtos.FieldOptions> implements DescriptorProtos.FieldOptionsOrBuilder
Protobuf type google.protobuf.FieldOptions
See Also:
  • Field Details

  • Method Details

    • newInstance

      protected Object newInstance(com.google.protobuf.GeneratedMessageV3.UnusedPrivateParameter unused)
      Overrides:
      newInstance in class com.google.protobuf.GeneratedMessageV3
    • getUnknownFields

      public final com.google.protobuf.UnknownFieldSet getUnknownFields()
      Specified by:
      getUnknownFields in interface com.google.protobuf.MessageOrBuilder
      Overrides:
      getUnknownFields in class com.google.protobuf.GeneratedMessageV3
    • getDescriptor

      public static final com.google.protobuf.Descriptors.Descriptor getDescriptor()
    • internalGetFieldAccessorTable

      protected com.google.protobuf.GeneratedMessageV3.FieldAccessorTable internalGetFieldAccessorTable()
      Specified by:
      internalGetFieldAccessorTable in class com.google.protobuf.GeneratedMessageV3
    • hasCtype

      public boolean hasCtype()
       The ctype option instructs the C++ code generator to use a different
       representation of the field than it normally would.  See the specific
       options below.  This option is not yet implemented in the open source
       release -- sorry, we'll try to include it in a future version!
       
      optional .google.protobuf.FieldOptions.CType ctype = 1 [default = STRING];
      Specified by:
      hasCtype in interface DescriptorProtos.FieldOptionsOrBuilder
      Returns:
      Whether the ctype field is set.
    • getCtype

       The ctype option instructs the C++ code generator to use a different
       representation of the field than it normally would.  See the specific
       options below.  This option is not yet implemented in the open source
       release -- sorry, we'll try to include it in a future version!
       
      optional .google.protobuf.FieldOptions.CType ctype = 1 [default = STRING];
      Specified by:
      getCtype in interface DescriptorProtos.FieldOptionsOrBuilder
      Returns:
      The ctype.
    • hasPacked

      public boolean hasPacked()
       The packed option can be enabled for repeated primitive fields to enable
       a more efficient representation on the wire. Rather than repeatedly
       writing the tag and type for each element, the entire array is encoded as
       a single length-delimited blob. In proto3, only explicit setting it to
       false will avoid using packed encoding.
       
      optional bool packed = 2;
      Specified by:
      hasPacked in interface DescriptorProtos.FieldOptionsOrBuilder
      Returns:
      Whether the packed field is set.
    • getPacked

      public boolean getPacked()
       The packed option can be enabled for repeated primitive fields to enable
       a more efficient representation on the wire. Rather than repeatedly
       writing the tag and type for each element, the entire array is encoded as
       a single length-delimited blob. In proto3, only explicit setting it to
       false will avoid using packed encoding.
       
      optional bool packed = 2;
      Specified by:
      getPacked in interface DescriptorProtos.FieldOptionsOrBuilder
      Returns:
      The packed.
    • hasJstype

      public boolean hasJstype()
       The jstype option determines the JavaScript type used for values of the
       field.  The option is permitted only for 64 bit integral and fixed types
       (int64, uint64, sint64, fixed64, sfixed64).  A field with jstype JS_STRING
       is represented as JavaScript string, which avoids loss of precision that
       can happen when a large value is converted to a floating point JavaScript.
       Specifying JS_NUMBER for the jstype causes the generated JavaScript code to
       use the JavaScript "number" type.  The behavior of the default option
       JS_NORMAL is implementation dependent.
       This option is an enum to permit additional types to be added, e.g.
       goog.math.Integer.
       
      optional .google.protobuf.FieldOptions.JSType jstype = 6 [default = JS_NORMAL];
      Specified by:
      hasJstype in interface DescriptorProtos.FieldOptionsOrBuilder
      Returns:
      Whether the jstype field is set.
    • getJstype

       The jstype option determines the JavaScript type used for values of the
       field.  The option is permitted only for 64 bit integral and fixed types
       (int64, uint64, sint64, fixed64, sfixed64).  A field with jstype JS_STRING
       is represented as JavaScript string, which avoids loss of precision that
       can happen when a large value is converted to a floating point JavaScript.
       Specifying JS_NUMBER for the jstype causes the generated JavaScript code to
       use the JavaScript "number" type.  The behavior of the default option
       JS_NORMAL is implementation dependent.
       This option is an enum to permit additional types to be added, e.g.
       goog.math.Integer.
       
      optional .google.protobuf.FieldOptions.JSType jstype = 6 [default = JS_NORMAL];
      Specified by:
      getJstype in interface DescriptorProtos.FieldOptionsOrBuilder
      Returns:
      The jstype.
    • hasLazy

      public boolean hasLazy()
       Should this field be parsed lazily?  Lazy applies only to message-type
       fields.  It means that when the outer message is initially parsed, the
       inner message's contents will not be parsed but instead stored in encoded
       form.  The inner message will actually be parsed when it is first accessed.
       This is only a hint.  Implementations are free to choose whether to use
       eager or lazy parsing regardless of the value of this option.  However,
       setting this option true suggests that the protocol author believes that
       using lazy parsing on this field is worth the additional bookkeeping
       overhead typically needed to implement it.
       This option does not affect the public interface of any generated code;
       all method signatures remain the same.  Furthermore, thread-safety of the
       interface is not affected by this option; const methods remain safe to
       call from multiple threads concurrently, while non-const methods continue
       to require exclusive access.
       Note that implementations may choose not to check required fields within
       a lazy sub-message.  That is, calling IsInitialized() on the outer message
       may return true even if the inner message has missing required fields.
       This is necessary because otherwise the inner message would have to be
       parsed in order to perform the check, defeating the purpose of lazy
       parsing.  An implementation which chooses not to check required fields
       must be consistent about it.  That is, for any particular sub-message, the
       implementation must either *always* check its required fields, or *never*
       check its required fields, regardless of whether or not the message has
       been parsed.
       
      optional bool lazy = 5 [default = false];
      Specified by:
      hasLazy in interface DescriptorProtos.FieldOptionsOrBuilder
      Returns:
      Whether the lazy field is set.
    • getLazy

      public boolean getLazy()
       Should this field be parsed lazily?  Lazy applies only to message-type
       fields.  It means that when the outer message is initially parsed, the
       inner message's contents will not be parsed but instead stored in encoded
       form.  The inner message will actually be parsed when it is first accessed.
       This is only a hint.  Implementations are free to choose whether to use
       eager or lazy parsing regardless of the value of this option.  However,
       setting this option true suggests that the protocol author believes that
       using lazy parsing on this field is worth the additional bookkeeping
       overhead typically needed to implement it.
       This option does not affect the public interface of any generated code;
       all method signatures remain the same.  Furthermore, thread-safety of the
       interface is not affected by this option; const methods remain safe to
       call from multiple threads concurrently, while non-const methods continue
       to require exclusive access.
       Note that implementations may choose not to check required fields within
       a lazy sub-message.  That is, calling IsInitialized() on the outer message
       may return true even if the inner message has missing required fields.
       This is necessary because otherwise the inner message would have to be
       parsed in order to perform the check, defeating the purpose of lazy
       parsing.  An implementation which chooses not to check required fields
       must be consistent about it.  That is, for any particular sub-message, the
       implementation must either *always* check its required fields, or *never*
       check its required fields, regardless of whether or not the message has
       been parsed.
       
      optional bool lazy = 5 [default = false];
      Specified by:
      getLazy in interface DescriptorProtos.FieldOptionsOrBuilder
      Returns:
      The lazy.
    • hasDeprecated

      public boolean hasDeprecated()
       Is this field deprecated?
       Depending on the target platform, this can emit Deprecated annotations
       for accessors, or it will be completely ignored; in the very least, this
       is a formalization for deprecating fields.
       
      optional bool deprecated = 3 [default = false];
      Specified by:
      hasDeprecated in interface DescriptorProtos.FieldOptionsOrBuilder
      Returns:
      Whether the deprecated field is set.
    • getDeprecated

      public boolean getDeprecated()
       Is this field deprecated?
       Depending on the target platform, this can emit Deprecated annotations
       for accessors, or it will be completely ignored; in the very least, this
       is a formalization for deprecating fields.
       
      optional bool deprecated = 3 [default = false];
      Specified by:
      getDeprecated in interface DescriptorProtos.FieldOptionsOrBuilder
      Returns:
      The deprecated.
    • hasWeak

      public boolean hasWeak()
       For Google-internal migration only. Do not use.
       
      optional bool weak = 10 [default = false];
      Specified by:
      hasWeak in interface DescriptorProtos.FieldOptionsOrBuilder
      Returns:
      Whether the weak field is set.
    • getWeak

      public boolean getWeak()
       For Google-internal migration only. Do not use.
       
      optional bool weak = 10 [default = false];
      Specified by:
      getWeak in interface DescriptorProtos.FieldOptionsOrBuilder
      Returns:
      The weak.
    • getUninterpretedOptionList

      public List<DescriptorProtos.UninterpretedOption> getUninterpretedOptionList()
       The parser stores options it doesn't recognize here. See above.
       
      repeated .google.protobuf.UninterpretedOption uninterpreted_option = 999;
      Specified by:
      getUninterpretedOptionList in interface DescriptorProtos.FieldOptionsOrBuilder
    • getUninterpretedOptionOrBuilderList

      public List<? extends DescriptorProtos.UninterpretedOptionOrBuilder> getUninterpretedOptionOrBuilderList()
       The parser stores options it doesn't recognize here. See above.
       
      repeated .google.protobuf.UninterpretedOption uninterpreted_option = 999;
      Specified by:
      getUninterpretedOptionOrBuilderList in interface DescriptorProtos.FieldOptionsOrBuilder
    • getUninterpretedOptionCount

      public int getUninterpretedOptionCount()
       The parser stores options it doesn't recognize here. See above.
       
      repeated .google.protobuf.UninterpretedOption uninterpreted_option = 999;
      Specified by:
      getUninterpretedOptionCount in interface DescriptorProtos.FieldOptionsOrBuilder
    • getUninterpretedOption

      public DescriptorProtos.UninterpretedOption getUninterpretedOption(int index)
       The parser stores options it doesn't recognize here. See above.
       
      repeated .google.protobuf.UninterpretedOption uninterpreted_option = 999;
      Specified by:
      getUninterpretedOption in interface DescriptorProtos.FieldOptionsOrBuilder
    • getUninterpretedOptionOrBuilder

      public DescriptorProtos.UninterpretedOptionOrBuilder getUninterpretedOptionOrBuilder(int index)
       The parser stores options it doesn't recognize here. See above.
       
      repeated .google.protobuf.UninterpretedOption uninterpreted_option = 999;
      Specified by:
      getUninterpretedOptionOrBuilder in interface DescriptorProtos.FieldOptionsOrBuilder
    • isInitialized

      public final boolean isInitialized()
      Specified by:
      isInitialized in interface com.google.protobuf.MessageLiteOrBuilder
      Overrides:
      isInitialized in class com.google.protobuf.GeneratedMessageV3.ExtendableMessage<DescriptorProtos.FieldOptions>
    • writeTo

      public void writeTo(com.google.protobuf.CodedOutputStream output) throws IOException
      Specified by:
      writeTo in interface com.google.protobuf.MessageLite
      Overrides:
      writeTo in class com.google.protobuf.GeneratedMessageV3
      Throws:
      IOException
    • getSerializedSize

      public int getSerializedSize()
      Specified by:
      getSerializedSize in interface com.google.protobuf.MessageLite
      Overrides:
      getSerializedSize in class com.google.protobuf.GeneratedMessageV3
    • equals

      public boolean equals(Object obj)
      Specified by:
      equals in interface com.google.protobuf.Message
      Overrides:
      equals in class com.google.protobuf.AbstractMessage
    • hashCode

      public int hashCode()
      Specified by:
      hashCode in interface com.google.protobuf.Message
      Overrides:
      hashCode in class com.google.protobuf.AbstractMessage
    • parseFrom

      public static DescriptorProtos.FieldOptions parseFrom(ByteBuffer data) throws com.google.protobuf.InvalidProtocolBufferException
      Throws:
      com.google.protobuf.InvalidProtocolBufferException
    • parseFrom

      public static DescriptorProtos.FieldOptions parseFrom(ByteBuffer data, com.google.protobuf.ExtensionRegistryLite extensionRegistry) throws com.google.protobuf.InvalidProtocolBufferException
      Throws:
      com.google.protobuf.InvalidProtocolBufferException
    • parseFrom

      public static DescriptorProtos.FieldOptions parseFrom(com.google.protobuf.ByteString data) throws com.google.protobuf.InvalidProtocolBufferException
      Throws:
      com.google.protobuf.InvalidProtocolBufferException
    • parseFrom

      public static DescriptorProtos.FieldOptions parseFrom(com.google.protobuf.ByteString data, com.google.protobuf.ExtensionRegistryLite extensionRegistry) throws com.google.protobuf.InvalidProtocolBufferException
      Throws:
      com.google.protobuf.InvalidProtocolBufferException
    • parseFrom

      public static DescriptorProtos.FieldOptions parseFrom(byte[] data) throws com.google.protobuf.InvalidProtocolBufferException
      Throws:
      com.google.protobuf.InvalidProtocolBufferException
    • parseFrom

      public static DescriptorProtos.FieldOptions parseFrom(byte[] data, com.google.protobuf.ExtensionRegistryLite extensionRegistry) throws com.google.protobuf.InvalidProtocolBufferException
      Throws:
      com.google.protobuf.InvalidProtocolBufferException
    • parseFrom

      public static DescriptorProtos.FieldOptions parseFrom(InputStream input) throws IOException
      Throws:
      IOException
    • parseFrom

      public static DescriptorProtos.FieldOptions parseFrom(InputStream input, com.google.protobuf.ExtensionRegistryLite extensionRegistry) throws IOException
      Throws:
      IOException
    • parseDelimitedFrom

      public static DescriptorProtos.FieldOptions parseDelimitedFrom(InputStream input) throws IOException
      Throws:
      IOException
    • parseDelimitedFrom

      public static DescriptorProtos.FieldOptions parseDelimitedFrom(InputStream input, com.google.protobuf.ExtensionRegistryLite extensionRegistry) throws IOException
      Throws:
      IOException
    • parseFrom

      public static DescriptorProtos.FieldOptions parseFrom(com.google.protobuf.CodedInputStream input) throws IOException
      Throws:
      IOException
    • parseFrom

      public static DescriptorProtos.FieldOptions parseFrom(com.google.protobuf.CodedInputStream input, com.google.protobuf.ExtensionRegistryLite extensionRegistry) throws IOException
      Throws:
      IOException
    • newBuilderForType

      public DescriptorProtos.FieldOptions.Builder newBuilderForType()
      Specified by:
      newBuilderForType in interface com.google.protobuf.Message
      Specified by:
      newBuilderForType in interface com.google.protobuf.MessageLite
    • newBuilder

      public static DescriptorProtos.FieldOptions.Builder newBuilder()
    • newBuilder

    • toBuilder

      Specified by:
      toBuilder in interface com.google.protobuf.Message
      Specified by:
      toBuilder in interface com.google.protobuf.MessageLite
    • newBuilderForType

      protected DescriptorProtos.FieldOptions.Builder newBuilderForType(com.google.protobuf.GeneratedMessageV3.BuilderParent parent)
      Specified by:
      newBuilderForType in class com.google.protobuf.GeneratedMessageV3
    • getDefaultInstance

      public static DescriptorProtos.FieldOptions getDefaultInstance()
    • parser

      public static com.google.protobuf.Parser<DescriptorProtos.FieldOptions> parser()
    • getParserForType

      public com.google.protobuf.Parser<DescriptorProtos.FieldOptions> getParserForType()
      Specified by:
      getParserForType in interface com.google.protobuf.Message
      Specified by:
      getParserForType in interface com.google.protobuf.MessageLite
      Overrides:
      getParserForType in class com.google.protobuf.GeneratedMessageV3
    • getDefaultInstanceForType

      public DescriptorProtos.FieldOptions getDefaultInstanceForType()
      Specified by:
      getDefaultInstanceForType in interface com.google.protobuf.GeneratedMessageV3.ExtendableMessageOrBuilder<DescriptorProtos.FieldOptions>
      Specified by:
      getDefaultInstanceForType in interface com.google.protobuf.MessageLiteOrBuilder
      Specified by:
      getDefaultInstanceForType in interface com.google.protobuf.MessageOrBuilder